Files
ad_trident/apps/global/heating.yaml

79 lines
3.1 KiB
YAML

heating_sensors:
module: virtualsensors
class: VirtualSensorsApp
priority: 10 # default priority app is 50, since most of them require sensors created by virtual sensors, it's important that virtual_sensors start first
sensors:
binary_sensor.heatpump_winter_mode:
trigger_conditions: false #sensor.month >= 10 or sensor.month <= 4
value_selector.target_temperature_heatpump:
attributes:
unit_of_measurement: °C
device_class: temperature
icon: mdi:thermometer
values:
winter_mode:
conditions: binary_sensor.heatpump_winter_mode
value: 18
default:
conditions: True
value: 27
smart_heating_templates_library:
module: templatelibrary
class: TemplateLibrary
priority: 1
templates_library:
clim_conditions:
trigger_conditions:
- "not binary_sensor.heatpump_winter_mode and (ext_temperature >= room_temperature or ext_temperature >= target_temperature or cant_open_window) and room_temperature >= (quick_resume ? target_temperature : (target_temperature + 1))"
- not binary_sensor.heatpump_winter_mode and self and (ext_temperature >= target_temperature or cant_open_window)
- binary_sensor.heatpump_winter_mode and room_temperature <= (target_temperature - 1) and ext_temperature <= 10
- binary_sensor.heatpump_winter_mode and self and room_temperature < target_temperature
blocking_conditions:
- binary_sensor.is_everybody_sleeping and not sleeping_in_the_room and not stay_on_while_sleeping
- not room_occupancy
- not binary_sensor.someone_home #and not (binary_sensor.someone_in_town and sensor.day_interval == 'Nuit')
- window_open
desk_heatpump:
module: smartheatpump
class: SmartHeatpump
entity: climate.desk_heatpump
templates_library: smart_heating_templates_library
constants:
window_open: binary_sensor.desk_window
ext_temperature: sensor.ext_front_temperature
room_temperature: sensor.desk_temperature
room_occupancy: binary_sensor.desk_occupancy
target_temperature: sensor.target_temperature_heatpump
cant_open_window: false #binary_sensor.cant_open_window
sleeping_in_the_room: false #binary_sensor.is_bureau_sleeping
quick_resume: binary_sensor.desk_heatpump_quick_resume
stay_on_while_sleeping: false
virtual_sensors:
sensors:
value_selector.desk_heatpump_fan_mode:
auto: binary_sensor.heatpump_winter_mode
quiet: True
target_temperature: sensor.target_temperature_heatpump
hvac_mode: "binary_sensor.heatpump_winter_mode ? 'heat' : 'cool'"
fan_mode: sensor.desk_heatpump_fan_mode
smart_conditions:
callback_delay: 10 # on the morning it can happen that we ask to start and stop the heat pump immediately afterwards which in result in the heat pump ignoring the second command
template_conditions: <clim_conditions>
quick_resume:
sensor: binary_sensor.desk_heatpump_quick_resume
reset_event: good_morning
#input_buttons:
# turn_on: input_button.clim_du_bureau_turn_on
# turn_off: input_button.clim_du_bureau_turn_off