Add heating sensor configuration and smart heat pump logic
This commit is contained in:
78
apps/global/heating.yaml
Normal file
78
apps/global/heating.yaml
Normal file
@@ -0,0 +1,78 @@
|
||||
heating_sensors:
|
||||
module: virtualsensors
|
||||
class: VirtualSensorsApp
|
||||
priority: 10 # default priority app is 50, since most of them require sensors created by virtual sensors, it's important that virtual_sensors start first
|
||||
|
||||
sensors:
|
||||
binary_sensor.heatpump_winter_mode:
|
||||
trigger_conditions: false #sensor.month >= 10 or sensor.month <= 4
|
||||
value_selector.target_temperature_heatpump:
|
||||
attributes:
|
||||
unit_of_measurement: °C
|
||||
device_class: temperature
|
||||
icon: mdi:thermometer
|
||||
values:
|
||||
winter_mode:
|
||||
conditions: binary_sensor.heatpump_winter_mode
|
||||
value: 18
|
||||
default:
|
||||
conditions: True
|
||||
value: 27
|
||||
|
||||
smart_heating_templates_library:
|
||||
module: templatelibrary
|
||||
class: TemplateLibrary
|
||||
priority: 1
|
||||
|
||||
templates_library:
|
||||
clim_conditions:
|
||||
trigger_conditions:
|
||||
- "not binary_sensor.heatpump_winter_mode and (ext_temperature >= room_temperature or ext_temperature >= target_temperature or cant_open_window) and room_temperature >= (quick_resume ? target_temperature : (target_temperature + 1))"
|
||||
- not binary_sensor.heatpump_winter_mode and self and (ext_temperature >= target_temperature or cant_open_window)
|
||||
- binary_sensor.heatpump_winter_mode and room_temperature <= (target_temperature - 1) and ext_temperature <= 10
|
||||
- binary_sensor.heatpump_winter_mode and self and room_temperature < target_temperature
|
||||
blocking_conditions:
|
||||
- binary_sensor.is_everybody_sleeping and not sleeping_in_the_room and not stay_on_while_sleeping
|
||||
- not room_occupancy
|
||||
- not binary_sensor.someone_home #and not (binary_sensor.someone_in_town and sensor.day_interval == 'Nuit')
|
||||
- window_open
|
||||
|
||||
desk_heatpump:
|
||||
module: smartheatpump
|
||||
class: SmartHeatpump
|
||||
entity: climate.desk_heatpump
|
||||
|
||||
templates_library: smart_heating_templates_library
|
||||
|
||||
constants:
|
||||
window_open: binary_sensor.desk_window
|
||||
ext_temperature: sensor.ext_front_temperature
|
||||
room_temperature: sensor.desk_temperature
|
||||
room_occupancy: binary_sensor.desk_occupancy
|
||||
target_temperature: sensor.target_temperature_heatpump
|
||||
cant_open_window: false #binary_sensor.cant_open_window
|
||||
sleeping_in_the_room: false #binary_sensor.is_bureau_sleeping
|
||||
quick_resume: binary_sensor.desk_heatpump_quick_resume
|
||||
stay_on_while_sleeping: false
|
||||
|
||||
virtual_sensors:
|
||||
sensors:
|
||||
value_selector.desk_heatpump_fan_mode:
|
||||
auto: binary_sensor.heatpump_winter_mode
|
||||
quiet: True
|
||||
|
||||
target_temperature: sensor.target_temperature_heatpump
|
||||
hvac_mode: "binary_sensor.heatpump_winter_mode ? 'heat' : 'cool'"
|
||||
fan_mode: sensor.desk_heatpump_fan_mode
|
||||
|
||||
smart_conditions:
|
||||
callback_delay: 10 # on the morning it can happen that we ask to start and stop the heat pump immediately afterwards which in result in the heat pump ignoring the second command
|
||||
template_conditions: <clim_conditions>
|
||||
|
||||
quick_resume:
|
||||
sensor: binary_sensor.desk_heatpump_quick_resume
|
||||
reset_event: good_morning
|
||||
|
||||
#input_buttons:
|
||||
# turn_on: input_button.clim_du_bureau_turn_on
|
||||
# turn_off: input_button.clim_du_bureau_turn_off
|
||||
Reference in New Issue
Block a user