Add bedroom heat pump configuration and update presence conditions for bedroom occupancy

This commit is contained in:
2026-05-27 23:06:16 +02:00
parent af6abec832
commit aa6fb42dd7
2 changed files with 39 additions and 0 deletions

View File

@@ -76,3 +76,39 @@ desk_heatpump:
#input_buttons:
# turn_on: input_button.clim_du_bureau_turn_on
# turn_off: input_button.clim_du_bureau_turn_off
bedroom_heatpump:
module: smartheatpump
class: SmartHeatpump
entity: climate.bedroom_heatpump
templates_library: smart_heating_templates_library
constants:
window_open: binary_sensor.bedroom_french_door
ext_temperature: sensor.ext_front_temperature
room_temperature: sensor.bedroom_temperature
room_occupancy: binary_sensor.bedroom_occupancy
target_temperature: sensor.target_temperature_heatpump
cant_open_window: false #binary_sensor.cant_open_window
sleeping_in_the_room: binary_sensor.is_bedroom_sleeping
quick_resume: binary_sensor.bedroom_heatpump_quick_resume
stay_on_while_sleeping: false
virtual_sensors:
sensors:
value_selector.bedroom_heatpump_fan_mode:
auto: binary_sensor.heatpump_winter_mode
quiet: True
target_temperature: sensor.target_temperature_heatpump
hvac_mode: "binary_sensor.heatpump_winter_mode ? 'heat' : 'cool'"
fan_mode: sensor.bedroom_heatpump_fan_mode
smart_conditions:
callback_delay: 10 # on the morning it can happen that we ask to start and stop the heat pump immediately afterwards which in result in the heat pump ignoring the second command
template_conditions: <clim_conditions>
quick_resume:
sensor: binary_sensor.bedroom_heatpump_quick_resume
reset_event: good_morning

View File

@@ -40,6 +40,9 @@ occupancy_sensors:
trigger_conditions: sensor.kitchen_last_motion <= 5
binary_sensor.restroom_occupancy:
trigger_conditions: sensor.restroom_last_motion <= 3
binary_sensor.bedroom_occupancy:
trigger_conditions: binary_sensor.is_bedroom_sleeping or binary_sensor.day_interval_night
blocking_conditions: not binary_sensor.someone_home
retain_condition.desk_occupancy:
retain_time: 5 * 60
conditions: