@@ -216,4 +216,34 @@ guestroom_heatpump:
|
||||
sensor: input_select.guestroom_heatpump_override
|
||||
reset_events:
|
||||
- good_morning
|
||||
- good_bye
|
||||
- good_bye
|
||||
|
||||
radiator_heating:
|
||||
module: boilerclimate
|
||||
class: BoilerClimate
|
||||
display_name: Chauffage radiateurs
|
||||
unique_id: appdaemon_radiator_heating
|
||||
indoor_sensor: sensor.corridor_temperature
|
||||
outdoor_sensor: sensor.ext_front_temperature
|
||||
target_temperature: 18
|
||||
initial_mode: heat
|
||||
|
||||
# Radiator heating enabled with the room-thermostat bridge CLOSED.
|
||||
# false keeps the climate/diagnostics but suppresses SetMode writes.
|
||||
send_commands: true
|
||||
command_interval: 60
|
||||
mqtt_topic: appdaemon/radiator_heating
|
||||
boiler_topic: themaplus-condens
|
||||
|
||||
# Starting values, to tune from observations with radiator circulation enabled.
|
||||
regulation:
|
||||
slope: 1.5
|
||||
offset: 10
|
||||
kp: 5
|
||||
ki: 0.2 # water °C / (room °C * hour)
|
||||
integral_limit: 8
|
||||
correction_limit: 12
|
||||
min_flow: 30
|
||||
max_flow: 50
|
||||
overheat: 0.5
|
||||
restart_margin: 0.1
|
||||