Enhance smart heating configurations to include sleeping conditions and update fan mode handling in SmartHeatpump
This commit is contained in:
@@ -27,7 +27,7 @@ smart_heating_templates_library:
|
||||
templates_library:
|
||||
clim_conditions:
|
||||
trigger_conditions:
|
||||
- "not binary_sensor.heatpump_winter_mode and (ext_temperature >= room_temperature or ext_temperature >= target_temperature or cant_open_window) and room_temperature >= (quick_resume ? target_temperature : (target_temperature + 1))"
|
||||
- "not binary_sensor.heatpump_winter_mode and (ext_temperature >= room_temperature or ext_temperature >= target_temperature or cant_open_window) and room_temperature >= ((quick_resume or sleeping_in_the_room)? target_temperature : (target_temperature + 1))"
|
||||
- not binary_sensor.heatpump_winter_mode and self and (ext_temperature >= target_temperature or cant_open_window)
|
||||
- binary_sensor.heatpump_winter_mode and room_temperature <= (target_temperature - 1) and ext_temperature <= 10
|
||||
- binary_sensor.heatpump_winter_mode and self and room_temperature < target_temperature
|
||||
@@ -50,8 +50,8 @@ desk_heatpump:
|
||||
room_temperature: sensor.desk_temperature
|
||||
room_occupancy: binary_sensor.desk_occupancy
|
||||
target_temperature: sensor.target_temperature_heatpump
|
||||
cant_open_window: false #binary_sensor.cant_open_window
|
||||
sleeping_in_the_room: false #binary_sensor.is_bureau_sleeping
|
||||
cant_open_window: binary_sensor.is_desk_sleeping
|
||||
sleeping_in_the_room: binary_sensor.is_desk_sleeping
|
||||
quick_resume: binary_sensor.desk_heatpump_quick_resume
|
||||
stay_on_while_sleeping: false
|
||||
|
||||
@@ -90,10 +90,10 @@ bedroom_heatpump:
|
||||
room_temperature: sensor.bedroom_temperature
|
||||
room_occupancy: binary_sensor.bedroom_occupancy
|
||||
target_temperature: sensor.target_temperature_heatpump
|
||||
cant_open_window: false #binary_sensor.cant_open_window
|
||||
cant_open_window: binary_sensor.is_bedroom_sleeping
|
||||
sleeping_in_the_room: binary_sensor.is_bedroom_sleeping
|
||||
quick_resume: binary_sensor.bedroom_heatpump_quick_resume
|
||||
stay_on_while_sleeping: false
|
||||
stay_on_while_sleeping: true
|
||||
|
||||
virtual_sensors:
|
||||
sensors:
|
||||
@@ -112,3 +112,36 @@ bedroom_heatpump:
|
||||
quick_resume:
|
||||
sensor: binary_sensor.bedroom_heatpump_quick_resume
|
||||
reset_event: good_morning
|
||||
|
||||
living_room_heatpump:
|
||||
module: smartheatpump
|
||||
class: SmartHeatpump
|
||||
entity: climate.living_room_heatpump
|
||||
|
||||
templates_library: smart_heating_templates_library
|
||||
|
||||
virtual_sensors:
|
||||
sensors:
|
||||
binary_sensor.living_room_any_window_open: binary_sensor.living_room_french_door or binary_sensor.living_room_window
|
||||
|
||||
constants:
|
||||
window_open: binary_sensor.living_room_any_window_open
|
||||
ext_temperature: sensor.ext_front_temperature
|
||||
room_temperature: sensor.living_room_temperature
|
||||
room_occupancy: binary_sensor.living_room_occupancy
|
||||
target_temperature: sensor.target_temperature_heatpump
|
||||
cant_open_window: binary_sensor.is_living_room_sleeping
|
||||
sleeping_in_the_room: binary_sensor.is_living_room_sleeping
|
||||
quick_resume: binary_sensor.living_room_heatpump_quick_resume
|
||||
stay_on_while_sleeping: false
|
||||
|
||||
target_temperature: sensor.target_temperature_heatpump
|
||||
hvac_mode: "binary_sensor.heatpump_winter_mode ? 'heat' : 'cool'"
|
||||
|
||||
smart_conditions:
|
||||
callback_delay: 10 # on the morning it can happen that we ask to start and stop the heat pump immediately afterwards which in result in the heat pump ignoring the second command
|
||||
template_conditions: <clim_conditions>
|
||||
|
||||
quick_resume:
|
||||
sensor: binary_sensor.living_room_heatpump_quick_resume
|
||||
reset_event: good_morning
|
||||
Reference in New Issue