Added a smart condition to the boiler

This commit is contained in:
Pierre committed 2026-10-11 10:13:37 +02:00
1 parent 6447d754ca
commit 79dd13f31d
4 files changed
+215 -6

No files matched your search

+9
View File
@@ -221,6 +221,7 @@ guestroom_heatpump:
radiator_heating:
module: boilerclimate
class: BoilerClimate
entity: climate.radiator_heating
display_name: Chauffage radiateurs
unique_id: appdaemon_radiator_heating
indoor_sensor: sensor.corridor_temperature
@@ -230,6 +231,14 @@ radiator_heating:
target_temperature: 18
initial_mode: heat
smart_conditions:
local_expressions:
outdoor_temperature: "sensor.ext_front_temperature < sensor.ext_back_temperature ? sensor.ext_front_temperature : sensor.ext_back_temperature"
trigger_conditions: binary_sensor.someone_home and outdoor_temperature < self.temperature
blocking_conditions:
- binary_sensor.group_windows
- binary_sensor.kitchen_french_door or binary_sensor.living_room_french_door or binary_sensor.bedroom_french_door
# Radiator heating enabled with the room-thermostat bridge CLOSED.
# false keeps the climate/diagnostics but suppresses SetMode writes.
send_commands: true