Added a smart condition to the boiler
This commit is contained in:
1 parent
6447d754ca
commit
79dd13f31d
4 files changed
+215
-6
No files matched your search
@@ -221,6 +221,7 @@ guestroom_heatpump:
|
||||
radiator_heating:
|
||||
module: boilerclimate
|
||||
class: BoilerClimate
|
||||
entity: climate.radiator_heating
|
||||
display_name: Chauffage radiateurs
|
||||
unique_id: appdaemon_radiator_heating
|
||||
indoor_sensor: sensor.corridor_temperature
|
||||
@@ -230,6 +231,14 @@ radiator_heating:
|
||||
target_temperature: 18
|
||||
initial_mode: heat
|
||||
|
||||
smart_conditions:
|
||||
local_expressions:
|
||||
outdoor_temperature: "sensor.ext_front_temperature < sensor.ext_back_temperature ? sensor.ext_front_temperature : sensor.ext_back_temperature"
|
||||
trigger_conditions: binary_sensor.someone_home and outdoor_temperature < self.temperature
|
||||
blocking_conditions:
|
||||
- binary_sensor.group_windows
|
||||
- binary_sensor.kitchen_french_door or binary_sensor.living_room_french_door or binary_sensor.bedroom_french_door
|
||||
|
||||
# Radiator heating enabled with the room-thermostat bridge CLOSED.
|
||||
# false keeps the climate/diagnostics but suppresses SetMode writes.
|
||||
send_commands: true
|
||||
|
||||
Reference in new issue
Block a user